Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
Search in posts
Search in pages
Filter by Categories
Author’ response
Author’s reply
Authors' response
Authors#x2019; response
Book Received
Book Review
Book Reviews
Centenary Review Article
Clinical Image
Clinical Images
Commentary
Communicable Diseases - Original Articles
Correspondence
Correspondence, Letter to Editor
Correspondences
Correspondences & Authors’ Responses
Corrigendum
Critique
Editorial
Errata
Erratum
Health Technology Innovation
IAA CONSENSUS DOCUMENT
Innovations
Letter to Editor
Malnutrition & Other Health Issues - Original Articles
Media & News
Notice of Retraction
Obituary
Original Article
Original Articles
Perspective
Policy
Policy Document
Policy Guidelines
Policy, Review Article
Policy: Correspondence
Policy: Editorial
Policy: Mapping Review
Policy: Original Article
Policy: Perspective
Policy: Process Paper
Policy: Scoping Review
Policy: Special Report
Policy: Systematic Review
Policy: Viewpoint
Practice
Practice: Authors’ response
Practice: Book Review
Practice: Clinical Image
Practice: Commentary
Practice: Correspondence
Practice: Letter to Editor
Practice: Obituary
Practice: Original Article
Practice: Pages From History of Medicine
Practice: Perspective
Practice: Review Article
Practice: Short Note
Practice: Short Paper
Practice: Special Report
Practice: Student IJMR
Practice: Systematic Review
Pratice, Original Article
Pratice, Review Article
Pratice, Short Paper
Programme
Programme, Correspondence, Letter to Editor
Programme: Commentary
Programme: Correspondence
Programme: Editorial
Programme: Original Article
Programme: Originial Article
Programme: Perspective
Programme: Rapid Review
Programme: Review Article
Programme: Short Paper
Programme: Special Report
Programme: Status Paper
Programme: Systematic Review
Programme: Viewpoint
Protocol
Research Correspondence
Retraction
Review Article
Short Paper
Special Opinion Paper
Special Report
Special Section Nutrition & Food Security
Status Paper
Status Report
Strategy
Student IJMR
Systematic Article
Systematic Review
Systematic Review & Meta-Analysis
Viewpoint
White Paper
Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
Search in posts
Search in pages
Filter by Categories
Author’ response
Author’s reply
Authors' response
Authors#x2019; response
Book Received
Book Review
Book Reviews
Centenary Review Article
Clinical Image
Clinical Images
Commentary
Communicable Diseases - Original Articles
Correspondence
Correspondence, Letter to Editor
Correspondences
Correspondences & Authors’ Responses
Corrigendum
Critique
Editorial
Errata
Erratum
Health Technology Innovation
IAA CONSENSUS DOCUMENT
Innovations
Letter to Editor
Malnutrition & Other Health Issues - Original Articles
Media & News
Notice of Retraction
Obituary
Original Article
Original Articles
Perspective
Policy
Policy Document
Policy Guidelines
Policy, Review Article
Policy: Correspondence
Policy: Editorial
Policy: Mapping Review
Policy: Original Article
Policy: Perspective
Policy: Process Paper
Policy: Scoping Review
Policy: Special Report
Policy: Systematic Review
Policy: Viewpoint
Practice
Practice: Authors’ response
Practice: Book Review
Practice: Clinical Image
Practice: Commentary
Practice: Correspondence
Practice: Letter to Editor
Practice: Obituary
Practice: Original Article
Practice: Pages From History of Medicine
Practice: Perspective
Practice: Review Article
Practice: Short Note
Practice: Short Paper
Practice: Special Report
Practice: Student IJMR
Practice: Systematic Review
Pratice, Original Article
Pratice, Review Article
Pratice, Short Paper
Programme
Programme, Correspondence, Letter to Editor
Programme: Commentary
Programme: Correspondence
Programme: Editorial
Programme: Original Article
Programme: Originial Article
Programme: Perspective
Programme: Rapid Review
Programme: Review Article
Programme: Short Paper
Programme: Special Report
Programme: Status Paper
Programme: Systematic Review
Programme: Viewpoint
Protocol
Research Correspondence
Retraction
Review Article
Short Paper
Special Opinion Paper
Special Report
Special Section Nutrition & Food Security
Status Paper
Status Report
Strategy
Student IJMR
Systematic Article
Systematic Review
Systematic Review & Meta-Analysis
Viewpoint
White Paper
View/Download PDF

Translate this page into:

Practice: Original Article
157 (
4
); 322-329
doi:
10.4103/ijmr.IJMR_1485_19

Effect of the timing of insertion of postpartum intrauterine contraceptive device (PPIUCD) copper T380A on expulsion rates

Department of Obstetrics & Gynecology, Jawaharlal Institute of Postgraduate Medical Education & Research, Puducherry, India

For correspondence: Dr Gowri Dorairajan, Department of Obstetrics & Gynecology, 2nd Floor, Women & Child Block, Jawaharlal Institute of Postgraduate Medical Education and Research, Dhanvantari Nagar, Puducherry 605 006, India e-mail: gowridorai@hotmail.com

Licence
This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
Disclaimer:
This article was originally published by Wolters Kluwer - Medknow and was migrated to Scientific Scholar after the change of Publisher.

Abstract

Background & objectives:

Postpartum intrauterine contraceptive device (PPIUCD) is well accepted and recommended for contraception. However, anxiety at the time of delivery may restrict the acceptance of a PPIUCD for its immediate insertion. So far there is limited evidence to conclude anything concrete on the association between the expulsion rates and the timing of insertion following a vaginal delivery. Thus, this study was undertaken to compare the expulsion rates in immediate and early insertions and their safety and complications.

Methods:

This prospective comparative study was carried out over 17 months on women delivering vaginally in a tertiary care teaching hospital in South India. A copper device (CuT380A) was inserted using Kelly’s placental forceps either within 10 min of placental delivery (immediate group, n=160) or between 10 min upto 48 h postpartum (early group, n=160). Ultrasound was done before discharge from the hospital. The expulsion rates and any other complications at six-week and three-month follow up were studied. Chi-square test was used to compare the difference in expulsion rates.

Results:

The expulsion rate was five per cent in the immediate compared to 3.7 per cent in the early group (no significant difference). In ten cases, the device was found to be in the lower uterus upon ultrasound before discharge. These were repositioned. There was no case with perforation, irregular bleeding or infection up to the three-month follow up. Higher age, higher parity, lack of satisfaction and motivation to continue were predictors of expulsion.

Interpretation & conclusions:

In the present study PPIUCD was found to be safe with overall expulsion in 4.3 per cent. It was marginally, though not significantly, higher in the immediate group.

Keywords

Contraception
copper device
copper T 380A
expulsion rates
intrauterine device
postpartum contraception

Postpartum intrauterine contraceptive device (PPIUCD) is a well accepted concept and was recommended and adopted by the Government of India since 20101. It can be inserted within 10 min of a placental delivery (immediate insertion) or after 10 min and upto 48 h of delivery2.3. However, higher expulsion rates reported with early versus immediate postpartum insertion are of concern4. In a systematic review from 20095, the early group was reported to have higher expulsion rates in comparison to the immediate insertion. However, many of the included studies were heterogeneous including both intra-caesarean and post-vaginal delivery insertion and including various intrauterine devices. Anxiety about the baby condition for the first 24 h may come in the way of whole-hearted acceptance of immediate insertion in spite of antenatal counselling6. The 2015 Cochrane analysis reported limited evidence to conclude on the expulsion rates based on the timing of insertion following vaginal delivery7. Hence, this study was undertaken with the primary objective of comparing the expulsion rates in the immediate and early PPIUCD insertions and furthermore of study to the safety and complications post PPIUCD insertions after vaginal deliveries.

Material & Methods

This prospective comparative study was carried out in department of Obstetrics and Gynecology, Jawaharlal Institute of Postgraduate Medical Education and Research, Puducherry, which is a tertiary care teaching hospital located in the south of India. The study was carried out from July 2017 till December 2018 after obtaining approval from the scientific committee and Institute Ethics Committee. There were about 1500 deliveries every month. Intense counselling was undertaken in the antenatal as well as during labour and in the post-natal wards as a part of the study. Women delivering vaginally and were motivated and willing for intrauterine contraceptive device (IUCD) insertion during the puerperal period were included in this study. Women with a prior caesarean scar, chorioamnionitis, prolonged rupture of membranes, postpartum complications and any known uterine malformations were excluded from the study. Intra-caesarean insertions were not included in the study. Based on the timing of insertion, two groups were studied, (i) immediate group: IUCD inserted within 10 min of placental delivery; and (ii) early group: devise inserted between 10 min upto 48 h postpartum. The participants were allocated to either group based on their preference. The device used was copper T 380A (CuT380A) (HLL Lifecare Ltd., Kerala, India).

Assuming alpha error of five per cent, power of 80 per cent, expulsion rate with postpartum insertion as 12 per cent4 and two times higher rates in the delayed postpartum insertion group5, the sample size come upto 160 per group. The device was inserted under aseptic precautions using Kelly’s Placental Forceps. All the insertions were carried out by consultants or post-degree doctors after on-site and on-the-job training. Ultrasound was carried out to confirm the correct placement of the device prior to discharge of every study participant from the hospital. The data were collected in a pro forma, and all the participants were followed up at six weeks and three months.

Statistical analysis: The data were analyzed using IBM SPSS Statistics for Windows version 22.0 (IBM Corp. Armonk, NY, USA). The two groups were compared for expulsion rates and other complications. All categorical variables such as age parity gravida and IUCD expulsion were expressed as percentages with 95 per cent confidence interval. Expulsion rates in the two groups were analyzed using the Chi-square test. P<0.05 was taken as statistically significant. Factors associated with expulsion were also analyzed.

Results

A total of 1550 women were counselled during the antenatal period and/or during labour for considering PIUCD insertion. 320 women (20.6% acceptance rate) accepted the IUCD and completed the study.

More than 85 per cent of the recruited women in either group belonged to Tamil Nadu. They delivered at the study hospital either because their maternal home was in Puducherry or because they sought to deliver there for the quality and free care.

Most of the demographic variables (Table I) were comparable in the two groups. We found that higher income of the husbands was more likely to be associated with early rather than immediate insertion (χ2=9.8015. P=0.002) and women with previous use of contraception were more likely to opt for immediate insertion (χ2=27.28. P=0.001).

Table I Frequency distribution of demographic characteristics of the two groups
Baseline demographic variables Immediate group (n=160), n (%) Early group (n=160), n (%) χ2, P
Age (yr)
18-23 105 (65.6) 111 (69.4) 0.54, 0.763
24-30 51 (31.9) 45 (28.1)
>30 4 (2.5) 4 (2.5)
Mean age (yr) 22.77 22.33
Wife’s education
Graduate 93 (58.1) 109 (68.1) 3.47, 0.176
More than graduate 66 (41.3) 50 (31.3)
Illiterate 1 (0.6) 1 (0.6)
Wife’s occupation
Working 11 (6.9) 12 (7.5) 0.046, 0.829
Housewife 149 (93.1) 148 (92.5)
Husband’s education
<graduate 117 (73.1) 124 (77.5) 1.02, 0.312
>graduate 43 (26.9) 35 (21.9)
Illiterate 0 (0) 1 (0.6)
Husband’s occupation
Professional 22 (13.8) 10 (6.2) 5.01, 0.082
Skilled 135 (84.4) 147 (91.9)
Semiskilled 3 (1.8) 3 (1.9)
Husband’s monthly income
>Rs. 2000 67 (41.9) 95 (59.4) 9.80, 0.002
<Rs. 2000 93 (58.1) 65 (40.6)
Religion
Hindu 150 (93.8) 149 (93.1) 0.44, 0.799
Muslim 5 (3.1) 7 (4.4)
Christian 5 (3.1) 4 (2.5)
State of residence
Tamil Nadu 146 (91.3) 142 (88.8) 0.55, 0.456
Pondicherry 14 (8.8) 18 (11.2)
Parity
Primipara 120 (75) 126 (78.8) 0.63, 0.426
>Primipara 40 (25) 34 (21.2)
Previous delivery (prior to index delivery)
Government hospital 36 (22.5) 32 (20) 1.05, 0.592
JIPMER 4 (2.5) 2 (1.3)
Not applicable (primigravida) 120 (75) 126 (78.7)
Previous abortions
Yes 21 (13.1) 14 (8.8) 1.57, 0.210
No 139 (86.9) 146 (91.3)
Use any contraceptive earlier
Yes 117 (73.1) 71 (44.4) 27.28, 0.001
No 43 (26.9) 89 (55.6)

In all the 320 cases recruited, the IUCD was inserted with Kelly’s placental forceps. There was no technical issues experienced at the time of inserting the IUCD. However, three in the immediate group and seven in the early group were found to have the IUCD inserted in the lower part of the uterus at the time of check scan. The same was repositioned to the fundus of the uterus.

At six week follow up (Table II), many women did not come for check up, but they responded to phone call. Five in the immediate group and six in the early group expelled the IUCD by six weeks. These women responded to phone call only and were not keen on reinsertion. Pain was the only complaint encountered. In nine women (1 in the immediate and 8 in the early group, out of a total 155 who came for the six week check up), the threads were not seen. They were reassured as the device was confirmed to be intrauterine by sonography. In the immediate group, there were three more expulsions (Table III). These three women were not willing for a reinsertion.

Table II Findings at six week follow up in the two groups
Study group Follow up at six weeks n (%) Speculum findings n (%) PV findings (n) USG (n) Complaints (n)
Immediate group (n=160) Direct check up=81 (50.6) Threads at vagina (same cut short)=80 (98.7) Uterus normal size (81) Device in the uterus (81) None (155) Pain (5)
Threads not seen out of cervix=1 (1.3)
Phone call=79 (9.4) Expelled (5)
Early (n=160) Direct check up=74 (46.25) Threads at vagina (same cut short)=66 (89.2) Uterus normal size (74) Device in the uterus (74) None (155) Pain (5)
Threads not seen=8 (10.8)
Phone call=86 (53.75) Expelled (6)

USG, ultrasonography; PV, per vaginal

Table III Follow up characteristics of the two groups at three months
Total Speculum findings Vaginal exam (n) USG (n) New complaints after six weeks (n)
Thread seen at introitus. Same cut short to cervix level, n (%) Threads seen at cervix level, n (%) Threads shortened to cervix level at six weeks itself now also seen at cervix, n (%)
Immediate (n=160−5 expelled before six weeks=155−3 new expulsion=152) 24 (15.8) 48 (31.6) 80 (52.6) Uterus normal size (152) Device in uterus (152) Pain (1)
Early (n=160−6 expelled before six weeks=154) no new expulsions 17 (11) 71 (46) 66 (43) Uterus normal size (154) Device in uterus (154) Pain (5)

USG, ultrasonography

The threads were cut short if these were lower down in the vagina. However, if seen only at level of the cervical os, these were not cut. The threads were seen in all the women at three-month follow up. In one woman, the thread was not seen at six weeks. This was seen at the level of cervix at three month follow up. It was observed that in the immediate group out of 160, there were eight expulsions; 104 women required cutting of thread (80 at 6 wk and another 24 at 3 months) and in 48 women, the thread was seen only at the level of cervix and was never cut.

In the early group out of 160, there were six expulsions. Eighty three women (66 at 6 wk and another 17 at 3 months) required cutting of the threads. The rest of the 71 women did not require cutting of threads as the threads were seen at the cervix only. The threads were not seen in eight women at six weeks in the early group. Five of these eight were at the level of cervix and three low in vagina at three month follow up.

The outcome variable in the two groups is shown in Table IV. There was a total of eight expulsions in the immediate (5%) and six (3.7%) in the early group. There was no case of perforation or excessive bleeding upto the three month follow up period. Ten women in the early and six in the immediate group had pain as the only complaint. None of the women were found to have clinical symptoms or signs of infection. Women in the immediate group were significantly more satisfied (n=155; 96.9%) as compared to those in the early group (n=143, 89.4%). The satisfaction was regarding the subjective feeling of use of IUCD as the method of contraception without any problems and regret (χ2=7.029, P=0.008, 95% CI - 0.87-0.98).

Table IV Comparison of primary and secondary outcome in the two groups
Complaints Immediate group, n (%) Early group, n (%) Statistical significance
Pain
Yes 6 (3.75) 10 (6.25) RR=1.64
χ2=1.008, df=2
P=0.317
95% CI=0.613-4.4
No 154 (96.25) 150 (93.75)
Bleeding infection
Yes 0 (0) 0 (0) -
No 160 (50) 160 (50)
Expulsion
Yes 8 (5) 6 (3.75) RR=0.75
χ2=0.299, df=1
P=0.585
95% CI=0.266-2.11
No 152 (95) 154 (96.25)
Satisfaction
Very 5 (3.1) 17 (10.6) χ2=7.02, df=1
P=0.008
95% CI=0.87-0.98
Not very 155 (96.9) 147 (89.4)

RR, relative risk; χ2, Chi-square value; df, degree of freedom; CI, confidence interval

At the end of the three months, all the patients who did not expel the IUCD were motivated to continue the IUCD. None of them requested a removal.

On univariate analysis (Table V), we found that women with lower age, lower parity, lower husband income, motivation to continue and higher satisfaction were less likely to expel the IUCD.

Table V Factors associated with expulsion of post-partum intrauterine contraceptive device in the study population (n=320)
Factor Expulsion χ2, P RR (95% CI)
No Yes Total (n=320)
Age (yr)
18-23 209 7 216 21.6565 1.2 (0.38-4.2)
24-30 92 4 96 <0.001
>30 5 3 8 11.57 (3.6-36.6)
Parity
Primipara 240 6 246 9.5302 4.4 (1.59-12.3)
Multipara 66 8 74 0.002
Religion
Hindu 288 11 299 12.9597 6.7 (2.1-21.1)
Muslim 9 3 12 0.002
Christian 9 0 9
Husband monthly income (₹)
>2000 159 3 162 4.9928 3.75 (1.06-13.22)
<2000 147 11 158 0.025
Motivation to continue
Yes 306 0 306 320
No 0 14 14 0.001
Satisfaction
Yes very 295 3 298 117.547
Only fair 11 11 22 0.001
Timing of insertion
Immediate 152 8 160 0.299 0.75 (0.266-2.11)
Early 154 6 160 0.585

RR, relative risk; CI, confidence interval

Discussion

In this study, the acceptance rate for PPIUCD was 21.3 per cent as compared to nine to 17 per cent rate of acceptance as observed in other studies8-10. In a six-centre study11, the acceptance rate was found to be only five per cent. In this study intense one-to-one and small group counselling sessions with videos and pamphlets were carried out. Counselling was carried out in the antenatal clinics as also during early labour and in the post-natal period. The reasons for non-acceptance in this study were not explored. In an earlier study from our group, we found that lack of family support, negative attitude and preferring to use natural methods were the causes for lower acceptance12.

In our study, all the insertions were carried out by consultants or qualified trained doctors. All the insertions were based on standard procedure using Kelly’s placental forceps. An overall expulsion rate of 4.4 per cent was found among the study participants. Higher expulsion rates have been described in other studies7,8,13. Expulsion rate varying from 3-7 per cent has been reported over the last few years14-16. In a study published in 2019 on 372 women with mixed population of vaginal and caesarean delivery, the expulsion rate was found to be 4.2 per cent17. The expulsion rate has declined with the standardized method of insertion with the Kelly’s placental forceps and improved training over the years.

In our study, the expulsion rate was marginally higher at five per cent in the immediate (post-placental) group and 3.7 per cent in the early group (beyond 10 min up to 48 h of placental delivery). A higher expulsion rate in the immediate group compared to the early group was also reported in other published observational studies11,18. Only two randomized trials19,20 have compared the expulsion rates of the device CuT380A based on the timing of insertion. In the trial by Ahuja and Rahtore19, 108 women were recruited into the two groups. Similar to our study in this study also, all insertions were with instrument. The authors found that that the expulsion rates were significantly higher at 24.11 per cent in the early (10 min to 48 h group) and 9.11 per cent in the immediate post-placental group. In the trial by Singh et al20, immediate post-placental IUCD insertion (n=100) demonstrated lower expulsion rate of 8.3 per cent compared to 10.5 per cent with early post-partum insertion though it was not found to be significant. In the latter study, caesarean cases were also included. It is not specified in these two trials whether ultrasonography was done after insertion20.

The present study ultrasonography was carried out for all women before discharge from the hospital. Three in the immediate and five in the early group were found to have a low placement of the device. The same were repositioned to the fundus of the uterus. Dias et al21 observed that the distance of lower end of the device from the internal os predicted expulsion with reasonable accuracy. Thus, routine ultrasound in our study helped us pick up eight cases which could have expelled the IUCD if not repositioned.

No case of infection in the present study was found to be similar to other reports8,22. As a policy, no antibiotics were prescribed following PPIUCD insertion. Strict aseptic measures were followed for delivery and no touch technique was followed for loading the device to the Kelly’s forceps.

Univariate analysis showed that lower age, lower parity, higher spousal income, motivation to continue and higher satisfaction were associated with lower risk of expulsion. In a study by Kant et al23 also, higher age and parity was associated with higher expulsion rates.

All these women were found to be normal on pelvic exam and sonography. Abdominal pain was the only complaint but all of them responded to pain killers.

The continuation rate among the women who did not expel was found to be 100 per cent in our study. This may possibly be due to the intense antenatal and post-delivery counselling by a committed team. The limitation of this study is that we designed the groups based on women’s preference. However, randomized would have been the best approach to bring out the differences in expulsion rate based on timing of insertion.

Overall, this study found PPIUCD to be safe with no observed complications of perforation, infection or bleeding. Higher age, higher parity, lower spousal income, lack of satisfaction and motivation to continue were found to be the predictors of expulsion. The findings of this study may only be extrapolated with inclusion of intense counselling in the antenatal clinic and follow up counselling in labour and post-delivery.

Financial support and sponsorship

The study was funded by the Indian Council of Medical Research (RCH/Ad hoc/33/2016-2017).

Conflicts of interest

None.

Acknowledgment:

None.

References

  1. . Ministry of Health and Family welfare, Government of India. Postpartum IUCD insertion manual. New Delhi: MoHFW, GoI; .
  2. . Available from:http://www.nrhmtn.gov.in/modules/PPIUCD%20Reference%20Ma nual.pdf
  3. . Postpartum intrauterine contraceptive device (PPIUD) services. Available from: https://www.glowm.com/pdf/Global%20PPIUD%20Reference%20Manual.pdf
  4. , , , . Post-placental intrauterine device insertion – A five year experience at a tertiary care centre in north India. Indian J Med Res. 2012;136:432-5.
    [Google Scholar]
  5. , , . Intrauterine device insertion during the postpartum period: A systematic review. Contraception. 2009;80:327-36.
    [Google Scholar]
  6. , , , . Effect of timing of insertion of postpartum intrauterine contraceptive device (PPIUCD) CuT380A on expulsion rates. In: In: RCOG World Congress 2019, 2019 June 17-19. Vol 126. London, UK: Category –Sexual and Reproductive Health. BJOG; . p. :217-24.
    [Google Scholar]
  7. , , , , , . Immediate postpartum insertion of intrauterine device for contraception. Cochrane Database Syst Rev. 2015;26:CD003036.
    [Google Scholar]
  8. , , , , , . Postpartum intrauterine device refusal in Delhi: Reasons analyzed. J Obstet Gynaecol India. 2018;68:208-13.
    [Google Scholar]
  9. , , , , , . Acceptability and factors associated with post-partum IUCD use among women who gave birth at bale zone health facilities, Southeast-Ethiopia. Contracept Reprod Med. 2018;3:16.
    [Google Scholar]
  10. , . Evaluation of safety, efficacy, and expulsion of post-placental and intra-cesarean insertion of intrauterine contraceptive devices (PPIUCD) J Obstet Gynaecol India. 2014;64:337-43.
    [Google Scholar]
  11. , , , , , , . FIGO postpartum intrauterine device initiative: Complication rates across six countries. Int J Gynaecol Obstet. 2018;143((Suppl 1)):20-7.
    [Google Scholar]
  12. , , , . Postpartum intrauterine contraceptive device: Knowledge and factors affecting acceptance among pregnant/parturient women attending a large tertiary health center in Puducherry, India. Int J Adv Med Health Res. 2017;4:69-74.
    [Google Scholar]
  13. , , , . IUCD;expulsion rate of PPIUCD (postpartum intrauterine contraceptive device) after vaginal delivery. Prof Med J. 2019;26:371-4.
    [Google Scholar]
  14. , , , , , , . Clinical outcomes of postpartum intrauterine devices inserted by midwives in Tanzania. Int J Gynaecol Obstet. 2018;143((Suppl 1)):38-42.
    [Google Scholar]
  15. , , , , , , . Women's experience with postpartum intrauterine contraceptive device use in India. Reprod Health. 2014;11:32.
    [Google Scholar]
  16. , , . Enhancing contraceptive usage by post-placental intrauterine contraceptive devices (PPIUCD) insertion with evaluation of safety, efficacy, and expulsion. Int J Reprod Contracept Obstet Gynecol. 2012;1:26-32.
    [Google Scholar]
  17. , , , . Efficacy and satisfaction rate in postpartum intrauterine contraceptive device insertion: A prospective study. Cureus. 2019;11:e5646.
    [Google Scholar]
  18. , , , , , , . Programmatic experience of post-partum IUD use in Zambia: An observational study on continuation and satisfaction. Eur J Contracept Reprod Health Care. 2016;21:356-60.
    [Google Scholar]
  19. , , . Continuation rates of postpartum intrauterine contraceptive device (IUCD) insertion: Randomised trial of post placental versus immediate postpartum insertion (conference abstract) BJOG. 2014;121((Suppl s2)):1-2.
    [Google Scholar]
  20. , , , . Comparison of immediate post placental and early postpartum intrauterine device insertion (abstract only) BJOG. 2014;121((Suppl s2)):7-8.
    [Google Scholar]
  21. , , , , , , . Use of ultrasound in predicting success of intrauterine contraceptive device insertion immediately after delivery. Ultrasound Obstet Gynecol. 2015;46:104-8.
    [Google Scholar]
  22. , , , . Evaluation of PPIUCD versus interval IUCD (380A) insertion in a teaching hospital of Western U. P. Int J Reprod Contracept Obstet Gynecol. 2013;2:204-8.
    [Google Scholar]
  23. , , , , , . Acceptance rate, probability of follow-up, and expulsion of postpartum intrauterine contraceptive device offered at two primary health centers, North India. J Family Med Prim Care. 2016;5:770-6.
    [Google Scholar]
Show Sections
Scroll to Top