Background and objectives
About 30% of patients with haemophilia A develop inhibitors to factor VIII (FVIII), subsequent to which treatment with FVIII concentrates becomes ineffective. The standard test for diagnosis of FVIII inhibitors is Nijmegen modified Bethesda assay (NBA). This test is not easily accessible and not widely available. We report development of a simple, rapid, equipment-free, latex agglutination test (LAT) for detecting antibodies to FVIII.
Methods
A novel, rapid semiquantitative point of care (POC) test using recombinant FVIII, covalently coupled to carboxylated latex beads and stabilised in an optimised buffer was established for detection of FVIII antibodies. The sensitisation conditions such as ionic strength of the incubation buffer, pH, antigen concentration, the covalent linking conditions and composition of storage buffer were optimised. The test was validated using approximately 200 samples from haemophilia patients and 47 samples from normal healthy volunteers. All samples from patients with haemophilia were tested for FVIII antibodies by NBA and FVIII antibody ELISA.
Results
The test was conducted by mixing antigen-sensitised beads with samples and observing agglutination within 5 min. A clear visual agglutination was observed in samples containing anti-FVIII antibodies. Compared to NBA, the sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of the POC test were 92%, 96%, 85%, and 98%, respectively. Working cost of per test is approximately 100 INR.
Interpretation and conclusions
This is a novel rapid POC assay for FVIII antibodies that can support immediate clinical decision-making in settings without access to specialised coagulation laboratories.
Keywords
How to cite this article: Jivani F, Kharat SV, Patil K, Saini GK, Dhawlarker A, Bharankar J, et al. A novel, rapid test for factor VIII antibodies in patients with haemophilia A.. Indian J Med Res. doi: 10.25259/IJMR_142_2026
The development of factor VIII (FVIII) inhibitors is one of the serious complications of factor replacement therapy in patients with congenital haemophilia A. The Nijmegen modification of the classical Bethesda assay1 is currently the standard method for screening and quantification of FVIII inhibitors. The World Federation of Haemophilia (WFH) and International Society on Thrombosis and Haemostasis (ISTH) have recommended NBA for diagnosis and monitoring inhibitor titre in patients with haemophilia who are on factor therapy.2,3 The method is extensive, time-consuming and resource intensive. The assay is marked with wide inter-laboratory variation in various quality control exercises.4 A more sensitive assay i.e. Nijmegen ultra-sensitive Bethesda Assay (NusBA) has also been reported recently, with a sensitivity up to 0.1 BU/mL.5
The antibodies are of two types; neutralising antibodies (NA) and non-neutralising antibodies (NNA). The NAs are detected by the clot-based assays like NBA whereas immunological tests like ELISA detect both NA and NNA.6 Diagnosis of NA is of immediate clinical assistance as the treatment is totally different in patients positive for NA and those without NA. NNAs are present both in haemophilia patients without inhibitors and healthy controls.7,8 There is no consensus yet on either the clinical impact of NNAs or prognostic implications, though more and more studies implicate them in modulating half-life of infused FVIII (t1/2) and FVIII clearance.9 Few studies have also implicated NNAs as biomarkers for an evolving FVIII inhibitor.10,11
Though NBA is the gold standard test for diagnosis of FVIII inhibitors, it is not universally available in all coagulation laboratories. Very often patients have to travel across States to get a report of their inhibitor status. What we need is a rapid test to detect FVIII antibodies, which has immediate clinical significance in bleeding patients and can provide a diagnosis within few minutes without the need of an equipment or any high-end technical expertise, the results of which will help to make immediate decision about patient care. We report development and testing a novel, rapid POC test for detection of FVIII antibodies.
Methods
Patients and controls
Blood samples were collected from around 200 patients with haemophilia A referred to our haemophilia treatment centre at the department of Haematology, KJ Somaiya Hospital & Research Centre, Mumbai, Maharashtra, India, for standardisation and validation of the present test; 39 samples were positive for FVIII inhibitors by NBA. This also included 15 patients who were on emicizumab prophylaxis using different low dose protocols, 5 samples with inhibitors also had coexisting lupus anticoagulants as detected by dilute Russel viper venom test (DRVVT). Samples from 47 normal healthy volunteers who had no history or family history of bleeding were also collected and included. Samples were collected only from those patients who were not transfused in the previous 2 wk. Patients who were part of any clinical trials were excluded. All blood samples were obtained after informed consent and the study was initiated after obtaining Institute Ethics Committee approval. The study duration is between December 2024 and January 2026.
Blood collection and processing
Nine mL of venous blood was collected in 3.2% trisodium citrate in the ratio 1:9 (anticoagulant: blood) and plasma was separated by spinning at 4500 rpm for 15 min. For serum, the blood was either collected in a clot activator vacutainer or a plain glass tube; the latter required the glass tubes to be placed at 37°C for 15 min for a better serum separation. The samples were spun twice at 4500 rpm at 4°C for 20 min. The supernatant containing the platelet poor plasma was separated and used for both NBA, ELISA and latex agglutination test (LAT). The remaining plasma samples and serum samples were aliquoted and stored in -70°C. Informed consent was obtained from the patients or their relatives and healthy subjects prior to blood collection.
Nijmegen modified Bethesda assay (NBA)
The inhibitor status of all haemophilia A samples except those on emicizumab was confirmed by NBA in the laboratory. Briefly, the method is as follows: All samples were incubated at 56°C for 30 min before the test to remove any residual FVIII. Subsequently, serial dilutions of patient plasma were done in FVIII deficient plasma which were mixed with equal volume of normal pooled plasma buffered with 0.1 M imidazole buffer, pH 7.4. The control for the test is equal volume of normal pooled plasma and buffer. After 2 h of incubation at 37°C, the residual FVIII activity was measured in each tube; the dilution of patient plasma closest to 50% of the standard was chosen for calculation of inhibitor titre.
FVIII antibody ELISA
An in-house ELISA was established in the laboratory for detection of FVIII binding antibodies. Briefly, the 96-welled maxisorp microtiter plates (NUNC, Denmark) were coated with full length recombinant FVIII (ADVATE, Takeda Pharmaceuticals, Japan), (1 IU/well) overnight at 4℃ in 50 µL of PBS buffer, pH 7.4. After washing with PBS with 0.05% tween 20, the wells were blocked with 3% bovine serum albumin (BSA) in PBS buffer for 1 h at room temperature. The washing steps were repeated and samples in different dilutions along with standards were added to the wells and incubated for 2 h at 37°C. The washing steps were repeated and horse radish peroxidase (HRP) conjugated anti-IgG (Invitrogen, USA) was added in 1:1000 dilution and incubated for another 2 h at room temperature. The substrate 3,3′,5,5′-tetramethylbenzidine (TMB) (Hi Media) was added and reaction was stopped after 15 min and optical density (OD) was read at 492 nM in an ELISA reader (Infinite® M Plex, Switzerland).
Sensitisation of latex beads
Different latex beads from different sources were tried for sensitisation with FVIII. They include carboxylated blue dyed microspheres, 3.0 µm (Polysciences, USA), dyed carboxyl polystyrene microspheres, Cabo Blue - 1.00 µm (Bangs Laboratories, USA), polystyrene latex super-carboxylated blue beads (300 nm) (Agilent Technologies, USA), and plain latex white beads (971 nm) (Agilent Technologies, USA). Multiple buffers for sensitisation process were attempted which included phosphate buffer saline (PBS), pH 7.4, 2-(N-Morpholino) ethanesulfonic acid (MES) buffer (0.025M), pH 9.2, glycine buffer saline (GBS), pH 9.2, carbonate-bicarbonate buffer (0.06M) pH 9.6, 1-ethyl-3-3(3-dimethylaminopropyl) carbodiimide (EDAC) (5%) in carbonate-bicarbonate buffer. The blocking agents like bovine serum albumin (BSA), fish gelatin, and casein were tried in different concentrations during the standardisation process. The recombinant FVIII proteins which were used included ADVATE (Takeda Pharmaceuticals, Japan), ELOCTATE (Bioverativ/Sanofi, USA), ESPEROCT (Novo Nordisk, Denmark), and REFACTO (Pfizer, USA).
The latex beads were coated with different concentrations of FVIII antigen using various buffer systems across a wide pH range from acidic to neutral and alkaline. The coating was performed under diverse incubation conditions that varied in duration and temperatures (22°C, 4°C, and 37°C). Blocking with different blocking agents was done at a wide concentration (1-20%) with varied incubation time. Finally, the sensitised beads were stored in storage buffer. Blocking was tried both before and after coating with FVIII antigen. The storage buffer using multiple stabilisers, and surfactants were tried and checked for reactivity and auto-agglutination at both room temperature and 4°C.
Internal validation
The sensitivity of the LAT was checked by using serial dilutions of two FVIII inhibitor positive samples (186 BU/mL and 72 BU/mL) and a standard FVIII inhibitor positive control obtained from commercial sources (FVIII Inh.Con native, 24 BU/mL; Technoclone, Vienna). The test was validated in 118 NBA negative and 39 NBA positive haemophilia A samples along with 47 samples from normal healthy volunteers. There were 15 patients who were on emicizumab prophylaxis. Five patients were also positive for lupus anticoagulants. Two patient samples with FVIII inhibitors (8.9 BU/mL and 6 BU/mL) were spiked with 0-50% recombinant FVIII (ADVATE, Takeda Pharmaceuticals, Japan) and 0-50 µg/mL concentration of emicizumab (F. Hoffmann-La Roche Ltd, Basel, Switzerland). Multiple aliquots were placed at 4℃ for stability check at different time intervals.
The cost of LAT was calculated based on the cumulative cost of all the reagents which included raw carboxylated latex beads, recombinant FVIII used for sensitisation, blocking agent, and the individual components of the coating, washing, and stabilisation buffers required for preparation of the test reagent. The testing time is the time starting from the addition of sample to FVIII sensitised latex beads until a visible clumping of the beads was observed in inhibitor positive samples.
Statistical analysis
The overall sensitivity and specificity were calculated taking into account all inhibitor positive samples using NBA as the gold standard.
Results
The principle of the present test is that specific antigen (FVIII) gets coated onto the hydrophobic surfaces of latex beads to detect the target antibody in biological sample. The antigen is attached to carboxyl groups of latex beads by covalent coupling. When the antigen coated latex beads are mixed with a biological sample containing the specific antibody against the coated antigen (FVIII antibody), the binding of multiple antigen and antibody molecules results in the formation of a cross-linked lattice, leading to the clumping or agglutination of latex beads, which is visible with naked eye.
Sensitisation of latex beads with FVIII
Following protocol was selected based on the specific and sensitive results obtained using positive and negative controls. The carboxyl polystyrene microspheres (Polysciences, PA, USA), 1μM in diameter in 2.5% suspension (4.55 X 1010 particles/mL) were covalently coupled to FVIII (Esperoct) overnight at RT in carbonate buffer pH 9.6 with EDAC. The beads were washed using 50 μL of PBS. The beads were blocked with different concentrations of BSA and optimum concentration and duration of blocking i.e. 5% for 2.5 h with gentle mixing at RT was selected. The other two blocking agents i.e. casein and fish gelatin gave nonspecific results in all concentrations tested. After washing the sensitised FVIII coated carboxyl beads with PBS pH 7.4, they were resuspended in the storage/stabilisation buffer. The final stabilising buffer included BSA (0.1%), sucrose (0.6%), polysorbate (0.01%), trizma (0.1%), NaCl (0.01%), glycine (0.02%), and glycerol (0.05%). The detailed protocol is shown in Supplementary Figure.
The test was performed on a testing card using 25 µL of citrated plasma or serum sample and 25 µL of FVIII sensitised carboxyl beads, and checking for agglutination after 5 min of gentle mixing. Inhibitor positive sample showed visible agglutination with clearing of background suspension within 2 min and formation of peripheral rim whereas inhibitor negative samples showed a uniform milky suspension without clumping ( Fig. 1). The antigen-antibody reaction created dense lattices which precipitated and settled down. During the rotation of the slide, any slight evaporation from the droplet drives these particles to the periphery forming a rim. High-titre inhibitor samples demonstrated visible agglutination up to a titre of ≥1 BU where it started clumping in ∼2 min. Agglutination weakened progressively with dilution. The lowest visually detectable agglutination corresponded approximately to the defined LOD.

Internal validation
The performance of LAT against in-house ELISA, commercial ELISA and NBA are shown in Table. As compared to the gold standard test i.e. NBA, the specificity and NPV were higher compared to sensitivity and PPV. The performance of LAT as compared to ELISA was better than NBA with an overall accuracy of 97.05%.
| Parameter | NBA | ELISA |
|---|---|---|
| True positive (n) | 36 | 43 |
| False positive (n) | 6 | 8 |
| True negative (n) | 159 | 160 |
| False negative (n) | 3 | 8 |
| Total no. of samples (N) | 204 | 219 |
| Sensitivity (%) | 92 | 84 |
| Specificity (%) | 96 | 95 |
| Positive predictive value (%) | 85 | 84 |
| Negative predictive value (%) | 98 | 95 |
| Accuracy (%) | 97 | 96 |
n, number of samples; N, total number of samples
The per-test cost of LAT, calculated from the total reagent expenditure including carboxylated latex beads, recombinant FVIII, blocking agent, and buffer components, was found to be approximately INR 100. The assay demonstrated a rapid turnaround time, with visible agglutination in inhibitor-positive samples observed within 5 min from the addition of plasma sample to the FVIII-sensitised latex beads.
Interfering factors
Ten out of 124 HA inhibitor negative patients and 3 out of 47 healthy controls were positive for NNAs. Among the 13 NNAs targeting factor VIII, 7 showed agglutination in LAT. Among the 15 patients on emicizumab prophylaxis, 4 patients gave history of past inhibitors diagnosed by NBA and all showed clear positive agglutination in the LAT test. In addition, inhibitor positive samples spiked with emicizumab up to a final concentration of 50 μg/mL and recombinant FVIII up to a final concentration of 50% did not show significant variation in the agglutination in the LAT. The five HA samples which were positive for LA by DRVVT test showed clear agglutination in the LAT.
Limit of detection (LOD)
The limit of detection was checked by using known patient samples. The LOD was found to be 1 BU/mL ( Fig. 2) detected using both inhibitor standard (FVIII Inh.Con.native, 24 BU/mL; Technoclone, Austria, Vienna) and inhibitor positive samples. Agglutination weakened on serial dilutions; the screening test was not in a linear correlation with NBA and is not a substitute to NBA.

Stability
The optimised stabilisation buffer for FVIII sensitised carboxyl beads consists of BSA (0.1%), sucrose (0.6%), surfactant (0.01%), trizma (0.1%), NaCl (0.01%), glycine (0.02%), and glycerol (0.05%). The stability of the antigen sensitised beads is checked at frequent intervals for 96 d till date and the beads showed similar degree of agglutination in positive samples and no aggregation in negative controls. The stability check is being continued; large scale validation and technology transfer are being explored ( Fig. 3).

Discussion
We have developed a simple qualitative, semi-quantitative and antibody-dependent LAT for FVIII antibody detection which is a quick, accurate, and affordable as compared to conventional assays and is easily implementable in any type of clinical setting. The test does not require a laboratory setting for its operation, which makes it suitable for use even in primary health care settings. It is equipment free and does not require any technical expertise for interpretation. With high sensitivity and specificity, the test enables point-of-care diagnosis for FVIII antibodies in haemophilia A, especially in low-resource healthcare settings.
One of the major problems in developing an immunological assay for FVIII inhibitors is the presence of NNAs in haemophilia patients without inhibitors and healthy controls.7,8 Majority of the NNAs are known to be low titre and low affinity antibodies.8 By adjusting different concentrations of BSA during the blocking procedure, we could block the low titre NNAs in the present study i.e four of 10 NNA from hemophilia A samples Blocking with 5% BSA gave the best results with an optimum sensitivity and specificity. This however compromised the sensitivity of the assay and we could not observe clear agglutination in samples with FVIII inhibitor titre <1 BU/mL. A clear agglutination could be observed in FVIII inhibitor positive cases with inhibitor titre >1 BU/mL.
The advantages of the present rapid test over the gold standard NBA include small volume of sample (25 µL vs. 3-5 mL blood), naked eye test (visually interpretable versus equipment based), rapid (3–5 min vs. 4-6 h for NBA), cost-effective (INR 100/test vs. INR 2,000–20,000 for NBA), type of sample (plasma/serum versus only citrated plasma) and noninterference (unaffected by LA, emicizumab and other nonspecific inhibitors versus positive interference in NBA).
Latex beads generally used for functionalisation are in general, either carboxyl (-COOH) or amine (-NH2) modified. These groups provide interacting residues for attachment to a protein molecule. Commercial, blue-coloured latex beads containing reactive -COOH moieties which provide negatively charged hydrophilic surface for the antigen were used in the present invention. The purpose of using coloured beads is to make the agglutinates clearly visible to the naked eye when captured on a white-coloured card. The latex beads with small particle size approximately 1.0 μM is desirable. Besides having high reactivity with the protein ligands, the surface modification with -COOH groups can improve the stability. We adopted covalent coupling method as it can result in more stable antigen-latex complex compared to passive adsorption method. This coupling of functional microspheres requires the activation of the beads for attachment which is done by 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide (EDAC) which proceeds with the formation of an unstable intermediate molecule and requires presence of protein of interest to bind to surface, which also depends on the ionic composition for the reaction mixture. Another major challenge in preparation of sensitised beads was nonspecific agglutination or auto-agglutination of the beads and this was avoided by blocking with high concentration of BSA.
Due to the inherent instability of FVIII in liquid form, achieving a stable liquid formulation remains one of the major challenges in developing FVIII-based diagnostic reagents. The commercially available products in the market, whether recombinant or plasma derived are in lyophilised formulation which is reconstituted prior to administration. Once reconstituted, shelf-life of the FVIII is relatively short and these factors have to be infused to patients within hours. Thus, the major task after establishing the test was to obtain a stabiliser reagent with optimal concentration and combination of individual stabilisers and surfactants and their possible synergistic effect. FVIII adsorbs very rapidly to multiple surfaces and reaches equilibrium within few hours. Surfactants are effective in minimising or preventing surface adsorption. Trehalose, a commonly-used protein stabiliser, was tried but failed to stabilise the FVIII sensitised beads in solution. The optimised FVIII sensitised latex reagent was found to be stable for > 3 mo without losing its sensitivity and specificity. The stability test is currently ongoing.
Lupus Anticoagulant are common in haemophilia patients and are known to interfere with all clot-based assays including NBA.12, Besides lupus anticoagulants, there are other nonspecific inhibitors which can affect the NBA results. Chromogenic assays are insensitive to lupus anticoagulants and other non-specific inhibitors of coagulation; however, these tests are expensive and not easily available.13 The LAT test, being immunological, is not affected by any of these nonspecific inhibitors.
One of the important limitations of NBA is the inaccuracy of the assay in the presence of residual FVIII. Therefore, NBA requires FVIII inactivation step of heating the plasma at 56°C for 30 min, thus further increasing the testing time. The LAT described here does not get affected by residual FVIII even at the highest concentration.
Four out of 15 patients were past-positive for FVIII inhibitors by NBA and the LAT could show clear agglutination in all 4 patients indicating that the test is not interfered by emicizumab. The spiked samples even in concentrations up to 50 μg/mL did not interfere with agglutination. Emicizumab is known to interfere only clot-based assays and therefore even the ELISA could detect FVIII antibodies in all 4 patients positive for FVIII inhibitors. This is a major advantage of the immunological tests including LAT. Many patients of haemophilia A are on low-dose and extremely low dose protocols.14 The NBA cannot detect inhibitors in these patients and the effect of the drug remains up to 6 mo. It is possible that these patients often have breakthrough bleeds or may have to undergo surgery for varied clinical indications. It is important to know the inhibitor status under these situations, to know the type of product the patients have to be treated with. Present test can prove to be highly useful to know the inhibitor status in emicizumab treated patients which will enable physicians to treat with specific products.
The major limitation of the present test is that it is a qualitative test and the titre of FVIII inhibitor cannot be obtained, though there is a good correlation between the degree of agglutination and the titre of inhibitors. Agglutination scores based on visual analysis is an option but it may not be too accurate and may be a challenge for inexperienced laboratory personnel.
In conclusion, we have developed a rapid, cost-effective screening test for FVIII antibodies which can be used in any emergency clinical setting where there is no access to coagulation laboratories. With high specificity and NPV, it can be a good screening test to rule out the presence of FVIII inhibitors. The negative results represent the absence FVIII inhibitors, while the positive results have to be confirmed by functional assays like NBA which will not only differentiate between NA and NNA but guide to initiate appropriate treatment.
Author contributions
SS, NT: Conceptualisation, study design, data acquisition, analysis, manuscript writing; FJ; Experimentation, data acquisition, analysis, manuscript writing; KP, GKS, AD, JB: Manuscript writing, SVK: Data acquisition, analysis manuscript writing. All authors have read and approved the final printed version of the manuscript.
Financial support and sponsorship
The study received the financial support from Indian Council of Medical Research, New Delhi, India under ICMR small grant scheme (IIRPSG-2024-01-01620).
Conflicts of Interest
None.
Use of Artificial Intelligence (AI)-Assisted Technology for manuscript preparation
The authors confirm that there was no use of AI-assisted technology for assisting in the writing of the manuscript and no images were manipulated using AI.
References
- Proceedings: A more uniform measurement of factor VIII inhibitors. Thromb Diath Haemorrh.. 1975;34:612.
- [PubMed] [Google Scholar]
- A detailed comparison of the performance of the standard versus the Nijmegen modification of the Bethesda assay in detecting factor VIII:C inhibitors in the haemophilia A population of Canada. Association of Hemophilia Centre Directors of Canada. Factor VIII/IX Subcommittee of Scientific and Standardization Committee of International Society on Thrombosis and Haemostasis. Thromb Haemost.. 1998;79:872-5.
- [PubMed] [Google Scholar]
- WFH Guidelines for the management of hemophilia, 3rd Edition. Haemophilia.. 2020;26:1-158.
- [CrossRef] [PubMed] [Google Scholar]
- The between-laboratory variation of factor VIII inhibitor testing: the experience of the external quality assessment program of the ECAT foundation. Semin Thromb Hemost.. 2009;35:786-93.
- [CrossRef] [PubMed] [Google Scholar]
- The Nijmegen ultra-sensitive Bethesda Assay detects very low-titer factor VIII inhibitors in patients with congenital and acquired hemophilia A. Thromb Res.. 2023;231:112-20.
- [CrossRef] [PubMed] [Google Scholar]
- Antibody profile in Indian severe haemophilia A patients with and without FVIII inhibitors. Immunol Lett.. 2016;169:93-7.
- [CrossRef] [PubMed] [Google Scholar]
- Characterization of the anti-factor VIII immunoglobulin profile in patients with hemophilia A by use of a fluorescence-based immunoassay. J Thromb Haemost.. 2015;13:47-53.
- [CrossRef] [PubMed] [PubMed Central] [Google Scholar]
- Distinct characteristics of antibody responses against factor VIII in healthy individuals and in different cohorts of hemophilia A patients. Blood.. 2013;121:1039-48.
- [CrossRef] [PubMed] [Google Scholar]
- FVIII-binding IgG modulates FVIII half-life in patients with severe and moderate hemophilia A without inhibitors. Blood.. 2016;128:293-6.
- [CrossRef] [PubMed] [Google Scholar]
- Antibody formation and specificity in Bethesda-negative brother pairs with haemophilia A. Haemophilia.. 2013;19:106-12.
- [CrossRef] [PubMed] [Google Scholar]
- Nonneutralizing antibodies against factor VIII and risk of inhibitor development in severe hemophilia A. Blood.. 2017;129:1245-50.
- [CrossRef] [PubMed] [Google Scholar]
- The spectrum of neutralizing and non-neutralizing anti-FVIII antibodies in a nationwide cohort of 788 persons with hemophilia A. Front Immunol.. 2024;15:1355813.
- [CrossRef] [PubMed] [PubMed Central] [Google Scholar]
- A chromogenic assay allows reliable measurement of factor VIII levels in the presence of strong lupus anticoagulants. Thromb Haemost.. 1998;79:237-8.
- [CrossRef] [PubMed] [Google Scholar]
- Freedom from bleeds with low-dose emicizumab prophylaxis in inhibitor-positive hemophilia A. J Hematol.. 2024;13:186-91.
- [CrossRef] [PubMed] [PubMed Central] [Google Scholar]